Power supply systems Rittal enclosures Modules PSM Current Busbars The current load capacity of each Rittal cabinet can be up to 96 A Increasing power requirements in modern IT structures are required in cabinets - Rittal Air Conditioning Rittal Electric Cabinets Rittal PDU Rittal Busbars Rittal fan
Source: edited by this website
Author:stationmaster
1/18/2024
166
author:Rittal cabinet, rittal cooling
key word:Rittal cabinet, rittal cooling, rittal busbar, rittal fan, rittal electric cabinet
power supply
Adopt a well-thought-out power distribution plan. Related to this is the increasing demand for black spots. With the new "Intelligent Power Distribution System" from Rittal, cabling and installation costs for Rittal enclosures can be significantly reduced. This modular system enables a basic configuration via a vertical input rail with three-phase input power. In the power supply Plug-in modules are available on the support rails. This is also possible during uninterrupted operation since the support profiles are mounted in a contact-protected manner.
Different Rittal Air Conditioner modules. Plugs with protective earth contact as well as IEC 320 etc. can be inserted into the support rail. Thanks to the contact protection, this can also be easily implemented by non-electricians as a plug-and-play system.
3 phase installation with maximum current 3x16A
In addition, a redundant three-phase input power supply for a Rittal cabinet configured with 3x16A can be implemented
The redundant current loop is completely separated from the three phases of the support rail. Each plug-in module grabs one phase from the support rail. Depending on the connection direction, input A or redundant input B. The modules can be expanded without interruption in operation.
Plug-in modules are equipped with an integrated overcurrent protection, whereby excessive current means that the module involved is switched off. The remaining modules remain running
Overvoltage protection can be integrated in the leads
The support rail can be integrated into the vertical frame of flexRack(i) without accessories
Via vertical support rails, the slots allow flexible use of the entire Rittal enclosures height and single-module redundant installation via separate power supplies. Scope of supply:
Current Rittal busbars are supplied with connection sockets, mounting fixtures and operating instructions.Rittal Air Conditioner do not have cables.
Further reading
Rittal cabinet、Rittal enclosures、Rittal Air Conditioner、Rittal electric cabinet
Quick navigation
rittal cooling,rittal busbar, rittal fan,rittal electric cabinet ,rittal fan and filter,rittal air conditioner,rittal lock,rittal panel lock,rittal enclosures,Cabinet factory,Chinese cabinet factory,Chinese sheet metal factory,Cabinet customization,china Rittal,china Rittal cabinet,china Rittal Air Conditioning