Welcome Guangzhou Chengjian Electronic Technology Co., Ltd
    中文版
Chengjian Technology Rittal-HEITEC,Subrack,Siemens PLC,Siemens Drilling,Jaka Robot,Piab Sucker
Consulting hotline(Wechat) 133-1887-1889
Popular keywords : Rittal cabinet Rittal Air Conditioning rittal busbar rittal fan rittal electric cabinet rittal Cabinets rittal Air Conditioners Cabinet factory Chinese cabinet factory Chinese sheet metal factory Cabinet customization
Contact Us
Guangzhou Chengjian Electronic Technology Co., Ltd
Mobile: 133-1887-1889
Tle: 020-22074194
Email: shenmc@chinarittal.com;gzhlsmc@gmail.com
Address: Room 306, Building 3, Jibang Science Park, No. 8, Jishan New Road Street, Tianhe District, Guangzhou, Guangdong, China

DK7979304 Rittal enclosures PDU Switch Version 4 C13 and 2 C19 Power 7.4KW32A Voltage 230V Width 44 Height 144 Length 450 - Rittal Manufacturing in Germany - Rittal Air Conditioning Repair Rittal Electric Cabinet Rittal Busbar Rittal Fan Rittal PDU DK7979.304

Source: edited by this website Author:stationmaster 4/10/2024 54


Rittal cabinet PDU switch type 220V power 7400W switch type PDU, 32A/1P, CEE, 4xC13+2xC19 packaging 1 piece weight/package 3.56kg

中文版:DK7979304
Product brand: Rittal
Rittal enclosures  PDU switched Model:DK7979304
PDU switched
High-end IT rack power distribution: Smart PDU with measurement function per phase and individually switchable output slots.
■ Rittal enclosures Product description
DK PDU switched, compact basic power distribution incl. energy measurement per phase, individually switchable output slots, with network interface and display, WHD: 450x44x144mm, IEC 60 320: 4x C13 + 2x C19
■ Rittal cabinet Product description
High-end power distribution in a compact design for IT network and server racks. With switching function and power measurement at the infeed or per phase.
■ Rittal enclosures Benefits
For vertical mounting, it may be attached in the zero-U space of the Rittal VX IT or TS IT rack with no need for tools
Colour coding of phases and fuse circuits (L1=pink, L2=black, L3=white)
Tool-free divider kit for VX IT
PDU self-supplied, no external power supply required
Measurement accuracy ± 1% (kWh) to EN 62 053-21
Programmable startup behaviour following voltage recovery (on/off/last status)
Programmable switching behaviour (time/programmable logic)
Integral real-time clock with battery buffering (max. 10 years, battery replaceable)
Integral electromagnetic buzzer for acoustic alarms
Adjustable limit values (warning/alarm) for voltage, current, output
Operating hours meter, total and cyclical, resettable
■ Rittal cabinet Technical specifications
Display/controller unit in the PDU enclosure rotatable through 180° and replaceable
Integral, fully-redundant power pack, power supply from all phases
Error-tolerant PDU power supply redundant across all phases
Voltage V, current A, frequency Hz
Active power, active energy, apparent power, apparent energy
Power factor (cosPhi) and phase angle
Zero conductor current measurement/load imbalance detection
Fuse monitoring for PDUs with integral fuse
Monitoring of the optionally available overvoltage protection
Bright TFT display, 128 x 128 pixels (RGB) with back-lighting and energy-saving mode to display output data and basic PDU configuration
Position sensors for display rotation and correct PDU representation on the website
Multi-colour LEDs (green/amber/red) to indicate switching states and warning/alarm limits per phase or infeed
Power LED to indicate voltage
Power-saving design, minimal intrinsic power consumption
■ Rittal enclosures Material
Aluminium section, black anodised
Slots: Plastic
■ Rittal cabinet Supply includes
Assembly parts
■ Rittal enclosures Options
Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure
Residual current measurement (type B) per infeed/phase/fuse
Monitoring of the optionally available overvoltage protection
CMC III CAN bus sensors may be connected for ambient monitoring, max. 16 sensors
Other enclosure colours are available
■ Rittal cabinet Measurement functions, description
Emergency power supply to PDU web server via PoE, sequential disconnection of the outputs
Switching function per output slot
Avoids overload peaks: Sequential activation of the outputs following voltage recovery
Relay states are saved even in the event of a power failure
Bistable relays: Low current consumption and high switching capacity, also suitable for higher starting currents up to max. 300 A
Grouping: Joint switching of multiple outputs
Measurement per phase or infeed
Powerful CPU (ARM Cortex A8)
Digital input (floating contact)
Additional alarm output/relay output (changeover contact)
Additional alarm output/relay output (changeover contact)
■ Rittal enclosures Dimensions
Width: 44mm
Depth: 144mm
Length: 450mm
■ Rittal cabinet No. of sockets and type
4xC13 / 2xC19
■ Rittal enclosures Rated operating voltage
230V (AC)
■ Rittal cabinet Rated current (max.)
32A
■ Rittal enclosures Power consumption
7.4kW
Infeeds
Qty.: 1
■ Rittal enclosures Phases per infeed: 1~
3 m
■ Rittal enclosures Type of electrical connection  CEE
■ Rittal enclosures Interfaces
Fully redundant Ethernet interface 10/100/1000 Mbit/s (2x RJ45, 1x with PoE)
USB 2.0 port (USB-A) for mass configuration, firmware updates & data logging
CAN bus interface (RJ 45) for a maximum of 8 ambient sensors
Serial interface RS232 (RJ12) for LTE unit, scripting, CLI
Use of own certificates/TLS 1.2
E-mail forwarding in case of alarm (SMTP)
User administration including rights management
LDAP(S)/Radius/Active Directory connection
Syslog server connection (max. 2 servers)
Fully redundant monitoring via 2nd network
■ Rittal enclosures Number RJ45 ports for sensor units max:2
■ Rittal enclosures Directives
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
■ Rittal enclosures Standards
EN 62368-1
EN 61000-3
EN 61000-4
EN 61000-6
EN 62053-21
■ Rittal enclosures Protocols
Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP
TCP/IP v4 & v6, DHCP, DNS
SNMP v1, v2c & v3, Modbus/TCP, OPC-UA
MIB for linking into 3rd party DCIM software
FTP/SFTP (update/file transfer)
■ Rittal enclosures Operating temperature range
5 °C...50 °C
■ Rittal enclosures Ambient humidity (non-condensing)
10...95 %
■ Rittal enclosures Storage temperature range
-20 °C...70 °C
■ Rittal enclosures To fit
Enclosure type:
VX IT enclosure frame:≥800mm
Enclosure type:
VX IT 19" mounting angles:≥
800mm
Packs of
1pc(s).
Weight/pack
3.56kg

Rittal cabinet, rittal cooling, rittal busbar, rittal fan, rittal electric cabinet,rittal enclosures

Rittal cabinet, rittal cooling, rittal busbar, rittal fan, rittal electric cabinet,rittal enclosures

Rittal cabinet, rittal cooling, rittal busbar, rittal fan, rittal electric cabinet Rittal enclosures

See page 734 of rittal 36 sample (36 sample download) for details. Download item 5 after opening

Customer Service
Contact information

Mobile:

133-1887-1889

Work shift:

Monday to Friday

Tel.:

020-22074194

QR code
Live Chat