Welcome Guangzhou Chengjian Electronic Technology Co., Ltd
    中文版
Chengjian Technology Rittal-HEITEC,Subrack,Siemens PLC,Siemens Drilling,Jaka Robot,Piab Sucker
Consulting hotline(Wechat) 133-1887-1889
Popular keywords : Rittal cabinet Rittal Air Conditioning rittal busbar rittal fan rittal electric cabinet rittal Cabinets rittal Air Conditioners Cabinet factory Chinese cabinet factory Chinese sheet metal factory Cabinet customization
Contact Us
Guangzhou Chengjian Electronic Technology Co., Ltd
Mobile: 133-1887-1889
Tle: 020-22074194
Email: shenmc@chinarittal.com;gzhlsmc@gmail.com
Address: Room 306, Building 3, Jibang Science Park, No. 8, Jishan New Road Street, Tianhe District, Guangzhou, Guangdong, China

DK7979213 Rittal enclosures PDU metered 12 C13 and 4 C1932A Power 7.4kW Voltage 230V Width 44 Deep 70 Length 1095 Cable Length 3m Electrical Connection Type Central and Eastern Europe - Made in Germany Rittal - Rittal Air Conditioning Rittal Electric Cabinet Rittal Busbar Rittal Fan Rittal PDU DK7979.213

Source: edited by this website Author:stationmaster 5/8/2024 24


Rittal enclosures voltage 220VPDU metered model power 7400W metered PDU, 32A/1P, CEE, 12xC13+4xC19 packaging 1 piece weight / packaging 3.7KG

中文版:DK7979213
Product brand: Rittal
Rittal enclosures  PDU metered plus Model:DK7979213
PDU metered
High-end IT rack power distribution: Smart PDU with energy measurement per phase, i.e. output requirement of an entire IT rack
PDU metered 16A/3P CEE 12xC13+4xC19
, DK PDU metered, Compact basic power distributor incl. energy mearsuremnt per phase, with network interface and display, WHD: 44x1095x70 mm
■ Rittal enclosures Product description
High-end power distribution in a compact design for IT network and server racks. With power measurement at the infeed or per phase
■ Rittal enclosures Benefits
For vertical mounting, it may be attached in the zero-U space of the Rittal VX IT or TS IT rack with no need for tools
Colour coding of phases and fuse circuits (L1=pink, L2=black, L3=white)
Tool-free divider kit for VX IT
PDU self-supplied, no external power supply required
Measurement accuracy ± 1% (kWh) to EN 62 053-21
Integral real-time clock with battery buffering (max. 10 years, battery replaceable)
Integral electromagnetic buzzer for acoustic alarms
Adjustable limit values (warning/alarm) for voltage, current, output
Operating hours meter, total and cyclical, resettable
Power-saving design, minimal intrinsic power consumption
■ Rittal enclosuresTechnical specifications
Display/controller unit in the PDU enclosure rotatable through 180° and replaceable
Integral, fully-redundant power pack, power supply from all phases
Error-tolerant PDU power supply redundant across all phases
Voltage V, current A, frequency Hz
Active power, active energy, apparent power, apparent energy
Power factor (cosPhi) and phase angle
Zero conductor current measurement/load imbalance detection
Fuse monitoring for PDUs with integral fuse
Bright TFT display, 128 x 128 pixels (RGB) with back-lighting and energy-saving mode to display output data and basic PDU configuration
Position sensors for display rotation and correct PDU representation on the website
Power LED to indicate voltage
■ Rittal enclosures Material
Aluminium section, black anodised
Slots: Plastic
■ Rittal enclosuresSupply includes
Assembly parts
■ Rittal enclosures Options
Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure
Residual current measurement (type B) per infeed/phase/fuse
Monitoring of the optionally available overvoltage protection
CMC III CAN bus sensors may be connected for ambient monitoring, max. 16 sensors
Other enclosure colours are available
■ Rittal enclosures Measurement functions, description
Measurement per phase or infeed
Powerful CPU (ARM Cortex A8)
Digital input (floating contact)
Additional alarm output/relay output (changeover contact)
■ Rittal enclosures Dimensions
Height:  44 mm
Depth:  70 mm
Length:  1095 mm
■ Rittal enclosuresNo. of sockets and type
12xC13+4xC19
■ Rittal enclosures Rated operating voltage
230V (AC)
■ Rittal cabinet Rated current (max.)
32A
■ Rittal enclosures Power consumption
7.4kW
Infeeds
Qty.: 1
Phases per infeed: 1~
Length of connection cable:3 m
■ Rittal enclosures Type of electrical connection:CEE 
■ Rittal enclosures Interfaces
USB 2.0 port (USB-A) for mass configuration, firmware updates & data logging
CAN bus interface (RJ 45) for a maximum of 8 ambient sensors
Serial interface RS232 (RJ12) for LTE unit, scripting, CLI
Use of own certificates/TLS 1.2
E-mail forwarding in case of alarm (SMTP)
User administration including rights management
LDAP(S)/Radius/Active Directory connection
Syslog server connection (max. 2 servers)
Fully redundant monitoring via 2nd network
Fully redundant Ethernet interface 10/100/1000 Mbit/s
■ Rittal enclosures Number RJ45 ports for sensor units max:2
■ Rittal enclosures Directives
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
■ Rittal enclosures Standards
EN 62368-1
EN 61000-3
EN 61000-4
EN 61000-6
EN 62053-21
■ Rittal enclosures Protocols
Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP
TCP/IP v4 & v6, DHCP, DNS
SNMP v1, v2c & v3, Modbus/TCP, OPC-UA
MIB for linking into 3rd party DCIM software
FTP/SFTP (update/file transfer)
■ Rittal enclosures Operating temperature range
5 °C...50 °C
■ Rittal enclosures Ambient humidity (non-condensing)
10...95 %
■ Rittal enclosures Storage temperature range
-20 °C...70 °C
■ Rittal enclosures To fit
Enclosure type: VX IT enclosure frame: ≥ 1200 mm
Enclosure type: VX IT 19" mounting angles: ≥ 1800 mm
Packs of
1pc(s).
Weight/pack
5.46kg

Rittal cabinet,rittal cooling,rittal busbar,rittal fan,rittal electric cabinet,rittal enclosures

Rittal cabinet,rittal cooling,rittal busbar,rittal fan,rittal electric cabinet,rittal enclosures

See page 733 of rittal 36 sample (36 sample download) for details. Download item 5 after opening

Customer Service
Contact information

Mobile:

133-1887-1889

Work shift:

Monday to Friday

Tel.:

020-22074194

QR code