author:Rittal cabinet, rittal cooling
key word:Rittal cabinet, rittal cooling, rittal busbar, rittal fan, rittal electric cabinet
Rittal cabinet power adapter
For trial operation or testing purposes of the MTCA system, including the front wiring terminals. The power adapter can be directly installed into 2U and 3U MTCA systems. In addition, a split kit is required for installation in the 4U and 5U systems of the Rittal cabinet.
Rittal Air Conditioning Technical Data:
·12V input 12V output 3.3V output
PicoTCA is a modular 2U, 19~component box that supports up to 12 AMCs and one MCH (full width, tight fit). The setting of the component box supports both the communication protocol based on AMC.1Type4 (PCle and Advance can be switched), AMC.2Type4 and AMC.2E2 (GbE), as well as the AMC.3 (SAS/SATA) protocol. SAS and SATAAMC cards are connected point by point through the bus backplane, enabling communication between each slot and its adjacent slots through port 2.3. The first batch of models will support one MCH (MicroTCA Carrier HUB) through the bus backplane. Design according to customer needs and negotiate with the bus backplane for supply.
Advantages at a Glance
Compliant with PICMGMEeadytoRun
Rittal air conditioning system
The 254mm box depth is suitable for installation in Rittal cabinets with a depth of 300mm, including AC/DC power supplies
Supports up to 12.5Gb/s
Support for replaceable air filters with different AMC type coefficients
High EMC electromagnetic compatibility protection
The sturdy industrial design ensures high impact and vibration safety and reliability
Rittal cabinets comply with NEBS
Completely installed, wired, and tested: 'ReadytoRun'
Rittal Air Conditioning Technical Data:
19~, 2U, depth 254mm AC/DC power supply, maximum 450w: 1 input voltage: minimum 90V AC - maximum 264V AC, with PFC - input frequency: minimum 47Hz - maximum 63Hz
- Output: 3.3vdc/max 3A.12vdc/max 38A
Cooling is achieved through two independent fan unit bus backplanes and AMC power connectors for HARTINGcon: card+quality integrated JTAG power supply,
For debugging and testing
Supports 12 AMCs (full width, "tight fit") according to AMC.1Type4E2S and AMC.2Type4E2S, as well as 1 MCH
Weight:_ 9kg
Working temperature of PLC control cabinet: -0 ° C to+45 ° C Environmental temperature: -40 ° C to+85 ° C Supply range:
1 rack mounted system 19~, 2u, depth 254mm,
2 rack mounted fans with air filters, 1 power supply,
1 bus backplane.
Quick navigation